Written for homeowners planning a practical outside water supply.

  • Gas Safe registered
  • MCS certified and RECC member
  • Vaillant Advanced Installer
Domestic water pipework
Accessible indoor isolation is part of a practical outside tap installation.

Covering:Kelso, Melrose, Galashiels, Coldstream, Duns, Haddington, Dunbar, North Berwick, Dalkeith

A useful outside tap needs more thought than a hole through the wall and a hose connector. The best position is easy to reach, drains without soaking the building and can be isolated from indoors before frost. Protection against water flowing backwards into the drinking supply is just as important as a watertight connection.

Start with how you will use it: filling a watering can, washing muddy boots or supplying a long garden hose. Then work backwards to the nearest suitable cold mains branch. The shortest visible route outside is not always the safest or simplest route through the house.

Choose the position before the tap

Put the outlet at a comfortable height with space underneath for a bucket and enough clearance to attach a hose without forcing the connector. Avoid door swings, narrow paths and places where drips could freeze across a walkway. Consider where water will land when someone fills a can or disconnects a hose. Constant wetting against masonry is not a good arrangement.

Inside, look for an accessible mains cold branch and a sensible route to the outside wall. A kitchen sink nearby often helps, but check what is behind units and appliances. The proposed drill point needs checking for concealed cables, gas pipes and other services. Do not drill speculatively because the brickwork looks clear from outdoors.

Select a suitable tap and pipe route

A good quality external bib tap should suit the water supply and the hose fittings you intend to use. Look for a secure wall fixing and parts that can be serviced without disturbing the pipe through the wall. A lockable design can be useful where the tap is publicly accessible, but it does not replace the internal isolation valve.

Keep exposed pipework short and supported. The installer should choose materials and fittings suitable for their location, including sunlight, physical damage and frost exposure. A push-on connector attached to an unsuitable internal pipe is not a durable outdoor installation. Longer routes to garages or distant garden points may need a different design and more substantial ground or building work.

Why a double check valve matters

A hose can sit in dirty water or remain connected to equipment. If supply pressure falls, contaminated water must not be drawn back towards the household supply. A double check valve is commonly specified as backflow protection for an ordinary domestic outside tap arrangement. It is a protective component, not a pressure booster or a cure for dripping.

A double check valve is not sufficient for every hose use. Higher contamination risks, including some chemical dosing, ponds or irrigation arrangements, may require a different protective arrangement with an air gap. Tell the plumber exactly what you plan to connect. Do not assume a tap advertised with an integral check valve makes every use compliant with Scottish Water Byelaws.

Provide indoor isolation and drainage

Ask for an accessible internal isolation valve on the outside tap branch, ideally somewhere you can reach without emptying a packed cupboard. It should isolate that branch rather than shutting off the whole kitchen. Label it if there is any doubt. A valve you cannot identify or operate easily will be little help when cold weather arrives.

Plan how the exposed section will drain once isolated. Opening the outdoor tap is not always enough if a check valve, a low point or the pipe layout traps water. A suitable drain point or revised pipe route may be needed. Ask the installer to demonstrate the actual winter shutdown procedure, rather than relying on a generic instruction to turn it off.

What the fitting job should involve

The plumber checks the supply, confirms the route and isolates the water before making connections. A suitable wall penetration must avoid concealed services and unnecessary damage to the building. Pipework needs appropriate protection through the wall and the opening should be weather sealed without obstructing building ventilation or drainage features. The external fitting needs a firm mounting, not support from the pipe alone.

After connection, the work includes checking for leaks, operating the tap and isolation valve, and confirming the specified backflow arrangement. Ask to see the connections under pressure and where any drain point is located. If the work would disturb gas pipework, stop and arrange a Gas Safe registered engineer for any gas work. An outside tap installation should not involve improvised alterations to gas services.

Frost protection and common mistakes

Before freezing weather, disconnect the hose and remove accessories that can retain water. Isolate and drain the exposed branch using the demonstrated procedure. Insulation and a fitted tap cover slow heat loss but do not prevent standing water freezing indefinitely. Leaving a hose reel connected can defeat otherwise sensible winter precautions by holding water at the outlet.

Do not assume a frost-resistant tap is immune to freezing. Such designs depend on correct installation, drainage and use, often including removal of the hose. Avoid forcing a stiff tap after a freeze or using a flame to free it. If the branch may have split, leave it isolated and arrange an inspection before restoring the supply.

Typical UK fitting costs and when to hire

Typical UK ranges for a straightforward outside tap supplied and fitted are around £120 to £250. Longer pipe runs, awkward access or additional backflow and drainage work can take the total to roughly £250 to £500 or more. Groundworks and distant garden supplies need separate assessment. These are indicative UK figures, not our prices; Graham Oliver Plumbing & Heating quotes after a survey.

Ask whether the quote includes internal isolation, appropriate backflow protection, wall making good, testing and VAT. A cheap kit is not the full job. Hire a plumber if you cannot identify the supply, safely isolate it or establish a compliant layout. Send photographs of the proposed outside position and the indoor pipework to make the initial discussion more useful.

Frequently asked questions

Does every garden hose need backflow protection?
The installation needs protection appropriate to the contamination risk. A double check valve commonly suits ordinary domestic tap use, but some hose applications need a higher level. Describe ponds, chemicals and irrigation equipment before the design is agreed.
Can an outside tap have hot water?
It needs a separate assessment of temperature control, scalding risks and backflow protection. Do not connect hot water to a standard cold arrangement as an afterthought. Explain the intended use so suitable equipment and safeguards can be selected.
Is a tap cover enough in winter?
No. A cover helps insulate the fitting but does not remove trapped water. Disconnect the hose and use the branch isolation and drainage arrangement. Check the manufacturer's instructions where a frost-resistant tap is fitted.
Can I leave the outside tap isolated all winter?
Yes, provided the exposed section has also been drained appropriately. Simply closing the internal valve can leave water trapped outside. Leave the tap and drain points in the positions specified by the installer for that particular arrangement.

Plan your outside tap

Share the proposed location and intended hose use so the supply and protection can be assessed.